China X-RAY TUBE KWESỊRỊ TOSHIBA E7242 Onye nrụpụta na onye na-eweta | Ụgbọ mmiri
X-RAY TUBE dabara TOSHIBA E7242

X-RAY TUBE dabara TOSHIBA E7242

X-RAY TUBE dabara TOSHIBA E7242

Nkọwa dị mkpirikpi:

Ngwa: Mgbakọ tube X-ray maka nyocha nyocha nke oge niile na nke nkịtị
ma ọ bụ redio dijitalụ na ụlọ ọrụ fluoroscopic
Atụmatụ ntinye: 12.5º Rhenium-Tungsten molybdenum lekwasịrị anya (RTM)
◆Ntụgharị uche: Obere 0.6, Nnukwu: 1.2
◆ Oke voltaji tube: 125kV
◆ Ejiri ụdị IEC60526 nweta ihe nkwụnye ọkụ dị elu.
◆High voltaji generator kwesịrị kwekọọ na IEC60601-2-7
◆ IEC Nhazi (IEC 60601-1: 2005): Klas I ME Equipment

Nkọwa ngwaahịa

Usoro ịkwụ ụgwọ & Mbupu:

Mkpado ngwaahịa

Ntuziaka ọkọlọtọ

Ntuziaka ọkọlọtọ

Aha

EN 60601-2-54:2009 Ngwa eletriki ahụike - Nkebi 2-54: Ihe ndị achọrọ maka nchekwa bụ isi na arụmọrụ dị mkpa nke akụrụngwa X-ray maka redio na redio
IEC60526 Igwe eriri igwe dị elu na njikọ oghere maka akụrụngwa X-ray ahụike
IEC 60522:1999 Mkpebi nke nzacha na-adịgide adịgide nke mgbakọ tube X-ray
IEC 60613-2010 Njirimara eletriki, thermal na loading nke tubes X-ray anode na-atụgharị maka nyocha ahụike
IEC60601-1: 2006 Akụrụngwa eletriki ahụike - Nkebi 1: Ihe achọrọ maka nchekwa bụ isi na arụmọrụ dị mkpa
IEC 60601-1-3: 2008 Ngwa eletriki ahụike - Nkebi 1-3: Ihe ndị achọrọ maka nchekwa bụ isi na arụmọrụ dị mkpa
IEC60601-2-28:2010 Ngwa eletriki ahụike - Nkebi 2-28: Ihe ndị achọrọ maka nchekwa bụ isi na arụmọrụ dị mkpa nke mgbakọ X-ray tube maka nyocha ahụike.
IEC 60336-2005 Akụrụngwa eletriki ahụike- Mgbakọ tube X-ray maka nyocha ahụike-Ụdị ebe ntụpọ

Nkọwa

●Edebere aha ya dị ka ndị a:

MWHX7110A

Tube

A

Igwe ọkụ dị elu nwere ntụzịaka ogo 90

MWTX71-0.6/1.2-125

B

Igwe ọkụ dị elu nwere ntụzịaka ogo 270

Data teknụzụ

Ngwongwo

Nkọwapụta

Ọkọlọtọ

Ike ntinye aha nke anode

F 1

F 2

IEC 60613

20kW (50/60Hz)

40kW (50/60Hz)

 

Ike nchekwa okpomọkụ anode

110kJ (150kHU)

IEC 60613

Ike kachasị mma nke anode

500W

 
Ike nchekwa ọkụ

900kJ

 
Oke. okpomọkụ na-aga n'ihu na-enweghị ikuku- okirikiri

180W

 
Ihe anodeIhe mkpuchi elu anode

Rhenium-Tungsten-TZM(RTM)

Rhenium-Tungsten (RT)

 
Akụkụ ebumnuche (Ntụgharị: axis ntụaka)

12,5 Celsius

IEC 60788

Mgbakọ tube X-ray filtration pụtara

1.5 mm Al / 75kV

IEC 60601-1-3

Uru aha (s) n'ebe ntụpọ

F1 (obere elekwasị anya)

F2 (nnukwu uche)

IEC 60336

0.6

1.2

 
X-ray tube nominal voltajiRadiographicFluoroscopic

125kV

100kV

IEC 60613

Data na kpo oku cathode Oke. ugbu a

Oke voltaji

≈ / AC, <20 kHz

 

F1

F 2

 

5.1A

≈79V

5.1 A

≈1214 V

 
Nhapu radieshon na 150 kV/3mA na anya 1m

0.5mGy/h

IEC60601-1-3

Mpaghara radieshon kacha

443×443mm na SID 1m

 
X-ray tube mgbakọ arọ

Ihe ruru. 18 n'arọ

 

Ọnọdụ maka ọrụ, nchekwa na njem

Oke

Oke ọrụ

Oke njem na nchekwa

Ọnọdụ okpomọkụ

Site na 10ruo 40

Site na -20to 70

Iru mmiri dị ala

≤75%

≤93%

Mmetụta barometric

Site na 70kPa ruo 106kPa

Site na 70kPa ruo 106kPa

 

Ụkpụrụ igodo Stator

1-phase stator

Ebe ule

C-M

C-A

Nguzogide ikuku

≈18.0…22.0Ω

≈45.0…55.0Ω

Voltaji na-arụ ọrụ nke ukwuu (agba ọsọ)

230V± 10%

Kwado voltaji na-arụ ọrụ(gbalite)

160V± 10%

voltaji breeki

70VDC

Na-agba ọsọ voltaji na ikpughe

80Vrms

Voltaji na-agba ọsọ na fluoroscopy

20V-40Vrms

Oge ịgba ọsọ (dabere na usoro mmalite)

1.2s

Ịkpachara anya na arụ ọrụ

1 .X-ray Radiationnchebe

Ngwaahịa a na-emezu ihe achọrọ nke IEC 60601-1-3.

Mgbakọ tube X-ray a na-ewepụta radieshon X-ray na-arụ ọrụ. Naanị ndị ọrụ ruru eru na ndị zụrụ azụ ka a na-ahapụ ka ha rụọ mgbakọ tube X-ray.

Mmetụta physiologic dị mkpa nwere ike imerụ onye ọrịa ahụ, nrụpụta sistemụ kwesịrị ịnwe nchebe kwesịrị ekwesị iji zere radieshon ionization.

2.Dielectric 0il

Mgbakọ tube X-ray nwere dielectric 0il dị maka nkwụsi ike dị elu. Dị ka ọ na-egbu egbu maka ahụ ike mmadụ,ọ bụrụ na ekpughere ya na mpaghara enweghị mmachi,a ga-atụfu ya dịka usoro iwu obodo.

3 .Operation Atmosphere

A naghị ekwe ka e jiri mgbakọ x-ray tube mee ihe na ikuku gas na-ere ọkụ ma ọ bụ nke na-emebi emebi ·

4.Gbanwee tube ugbu a

Dabere na ọnọdụ ọrụ,enwere ike gbanwee njirimara filament.

Mgbanwe a nwere ike imetụta mkpughe nke oke ọnụ na mgbakọ tube X-ray.

Iji gbochie mgbakọ tube X-ray mebiri emebi,gbanwee tube ugbu a mgbe niile.

E wezụga mgbe X-ray tube nwere arcing Nsogbu na aleji oge eme ihe,chọrọ mgbanwe nke tube ugbu a.

5.X-ray Tube Okpomọkụ Ebe obibi

Emetụkwala n'elu ụlọ ụlọ X-ray tube obere oge ka arụchara ọrụ n'ihi oke okpomọkụ.

Nọgidere tube X-ray ka ọ dị jụụ.

6Oke ọrụ

Tupu eji,biko gosi na ọnọdụ gburugburu ebe obibi dị n'ime Imitts na-arụ ọrụ.

7.Arụ ọrụ ọ bụla

P1ease kpọtụrụ SAILRAY ozugbo,ọ bụrụ na achọpụtara adịghị arụ ọrụ ọ bụla nke mgbakọ tube X-ray.

8.Mkpofu

Mgbakọ tube X-ray yana tube nwere ihe ndị dị ka mmanụ na ọla dị arọ nke a ga-emesi obi ike na gburugburu ebe obibi enyi na ikpofu kwesịrị ekwesị dị ka ụkpụrụ iwu obodo siri dị. ihe ọmụma teknụzụ achọrọ ma ga-eweghachi mgbakọ tube X-ray maka mkpofu.

Biko kpọtụrụ ndị ahịa maka ebumnuche a.

Emission akụkụ nke cathode

图片

Ọ bụrụ (A) Obere ntụpọ

图片1.2焦点

Ọ bụrụ (A) Nnukwu Focal Spot

Ibu otu na usoro

Ọnọdụ: Tube Voltage Nkeji atọ

Ugboro ike Stator 50Hz/60Hz

Ia (mA)

图片4

t(s)

Ia (mA)

图片3

t(s)

Kpo oku na obi jụrụ akụkụ nke anode

  IEC60613

图片5

Kpọọ ọkụ na nju oyi nke mgbakọ tube X-ray

Njirimara okpomọkụ nke ụlọ

图片6

X-ray tube mgbakọ akụkụ eserese

SRMWHX7110A

图片7

Mgbakọ nzacha na ngalaba Cross Port

图片 27

Rotor Njikọ Wiring

图片 28

  • Nke gara aga:
  • Osote:

  • Ọnụ ego kacha nta: 1pc

    Ahịa: mkparita uka

    Nkọwa ngwugwu: 100pcs kwa katọn ma ọ bụ ahaziri dị ka ọnụọgụgụ

    Oge nnyefe: 1 ~ 2 izu dị ka ọnụọgụgụ

    Usoro ịkwụ ụgwọ: 100% T / T n'ihu ma ọ bụ WESTERN UNION

    Ịkwanye ikike: 1000pcs / ọnwa

    Dee ozi gị ebe a ziga anyị ya