China Dental X-ray Tube CEI Ox_70-P emeputa na soplaya |Ụgbọ mmiri
Igwe X-ray eze nke CEI Ox_70-P

Igwe X-ray eze nke CEI Ox_70-P

Igwe X-ray eze nke CEI Ox_70-P

Nkọwa dị mkpirikpi:

Ụdị: tube x-ray anode na-akwụsị
Ngwa: Maka nkeji x-ray eze intra-onu
Ụdị: KL1-0.8-70
Dakọtara na CEI OC70-P
Integrated elu àgwà iko tube

Nke a tube nwere lekwasịrị anya 0.8, na dị maka kacha tube voltaji 70 kV.

Awụnyere n'otu ogige ahụ na ihe ngbanwe dị elu


Nkọwa ngwaahịa

Usoro ịkwụ ụgwọ & Mbupu:

Mkpado ngwaahịa

Nkọwa

KL1-0.8-70 ọdụ anode X-Ray Tube emebere nke ọma maka nkeji x-ray eze intra-oral ma dị maka voltaji ọkpọkọ ọnụ nwere sekit emeziri onwe ya.
KL1-0.8-70 tube nwere otu elekwasị anya.
Igwe mmiri dị elu agbakwunyere nwere imewe iko nwere otu ebe etinyere nke ọma yana anode gbasiri ike.
Ike nchekwa okpomọkụ nke anode dị elu na-eme ka ọtụtụ ngwa dị iche iche maka ngwa eze intra-oral.Ihe pụrụ iche emebere anode na-enyere aka ikpo ọkụ ọkụ dị elu nke na-eduga n'inweta onye ọrịa dị elu na ndụ ngwaahịa dị ogologo.A na-ahụta mkpụrụ ọgwụ dị elu mgbe niile n'oge ndụ tube niile site na ebumnuche tungsten dị elu.A na-akwado ịdị mfe nke ntinye n'ime ngwaahịa sistemu site na nkwado teknụzụ dị ukwuu.

Ngwa

KL1-0.8-70 ọdụ anode X-Ray Tube emebere nke ọma maka nkeji x-ray eze intra-oral ma dị maka voltaji ọkpọkọ ọnụ nwere sekit emeziri onwe ya.

Data teknụzụ

Voltaji Tube aha aha 70kV
Voltage Inverse Nominal 85kV
Ọnụ Focal Spot 0.8 (IEC60336/1993)
Oke.Anode Okpomọkụ ọdịnaya 7000J
Oke.Ọrụ Na-aga n'ihu ugbu a 2mA x 70kV
Oke.Ọnụego jụrụ oyi 140W
Akụkụ ebumnuche 19°
Njirimara Filament 1.8 - 2.2A, 2.4 - 3.3V
Nzacha na-adịgide adịgide Min.0.6mm Al / 50 kV (IEC60522/1999)
Ihe ezubere iche Tungsten
Ike ntinye anode aha aha 840W

Foto zuru ezu

nkọwa

Uru asọmpi

Ike nchekwa okpomoku anode dị elu yana jụrụ oyi
Mmụba dose dị elu mgbe niile
Ndụ mara mma

Uru asọmpi

Tupu eji ya eme ihe, gbanye tube ahụ dị ka usoro nhazi oge enyere n'okpuru ruo mgbe a ga-enweta voltaji tube achọrọ.Ọmụmaatụ enyere – kwesịrị ka emegharia site n'aka onye nrụpụta wee kọwapụta ya na mpempe data nke akụkụ ahụ:

Nhazi oge mbubata na oge nri maka oge efu (ihe karịrị ọnwa isii)Oge:

Mgbe tube ugbu a bụ ejighị n'aka na sizinin, ozugbo gbanyụọ tube voltaji na mgbe otu nkeji nke 5 nkeji ma ọ bụ karịa, dịkwuo tube voltaji nwayọọ nwayọọ si ala voltaji mgbe ijide n'aka na tube ugbu a kwụsiri ike.A ga-ebelata arụmọrụ voltaji na-eguzogide nke tube unit ka oge ikpughe na ọnụ ọgụgụ nke ọrụ na-abawanye.Achọpụta mmetụta unyi nwere ike ịpụta n'elu oghere x-ray a na-eche n'elu site na mwepu ntanye n'oge isi nri.Ihe omume ndị a bụ otu usoro iji weghachite arụmọrụ voltaji na-adịgide adịgide n'oge ahụ.Ya mere, ọ bụrụ na ọ na-arụ ọrụ kwụsiri ike na voltaji tube kacha nke oge na-esote ha, enwere ike iji nkeji tube na-enweghị nnyonye anya na arụmọrụ eletrik ya nke na-eji.

Ịdọ aka ná ntị

Gụọ ịdọ aka ná ntị tupu i jiri tube

 

X-ray tube ga-ewepụta X-ray mgbe a na-enye ike ya na nnukwu voltaji, ekwesịrị ịchọrọ ihe ọmụma pụrụ iche na ọ dị mkpa ka a kpachara anya mgbe ị na-ejikwa ya..

 

1.Naanị ọkachamara tozuru oke nwere ihe ọmụma tube X-ray kwesịrị ịgbakọta,na-echekwa ma wepụ tube ahụ.

2.Ekwesịrị ilebara anya nke ọma iji zere mmetụta siri ike na ịma jijiji na tube n'ihi na ejiri iko na-emebi emebi mee ya.

3.A ghaghị iwere ihe nchebe radieshon nke akụkụ tube nke ọma.

4.Opekempe anya mgba afa (SSD) na nzacha kacha nta kwesịrị dakọtara na ụkpụrụ ahụ wee zute ọkọlọtọ..

5.Sistemu kwesịrị inwe sekit nchebe oke ibu kwesịrị ekwesị,Enwere ike imebi tube ahụ n'ihi naanị otu ọrụ ibufe.

6.Mgbe achọpụtara ihe ọ bụla na-adịghị mma n'oge arụ ọrụ,Gbanyụọ ọkụ ozugbo wee kpọtụrụ onye injinia ọrụ.

7.ọ bụrụ na tube nwere ọta ndu,iji tufuo ọta ndu ga-emezurịrị iwu gọọmentị.


  • Nke gara aga:
  • Osote:

  • Ọnụ ego kacha nta: 1pc

    Ahịa: mkparita uka

    Nkọwa ngwugwu: 100pcs kwa katọn ma ọ bụ ahaziri dị ka ọnụọgụgụ

    Oge nnyefe: 1 ~ 2 izu dị ka ọnụọgụgụ

    Usoro ịkwụ ụgwọ: 100% T / T n'ihu ma ọ bụ WESTERN UNION

    Ịkwanye ikike: 1000pcs / ọnwa

    Dee ozi gị ebe a ziga anyị ya