Emepụtara ma mepụta ngwaahịa a na nkwekọrịta na iwu, ntụzịaka na ụkpụrụ imewe:
◆ Ntuziaka Council 93/42/EEC nke 14 June 1993 gbasara ngwaọrụ ahụike(Akara CE).
TS EN ISO 13485 Ngwa ahụike - Sistemụ njikwa ogo - Ihe achọrọ maka usoro iwu.
ebumnuche..
TS EN ISO 14971 Ngwa ahụike - Ngwa njikwa ihe egwu na ngwaọrụ ahụike
TS EN ISO 15223-1 ngwaọrụ ahụike - akara iji jiri akara ngwaọrụ ahụike, akara na ozi a ga-enye - Nkebi 1: Ihe ndị chọrọ n'ozuzu
◆International Electrotechnical Commission (IEC), a na-atụle ụkpụrụ ndị a karịsịa.
Ntuziaka ọkọlọtọ | Aha |
EN 60601-2-54:2009 | Ngwa eletriki ahụike - Nkebi 2-54: Ihe ndị achọrọ maka nchekwa bụ isi na arụmọrụ dị mkpa nke akụrụngwa X-ray maka redio na redio |
IEC60526 | Igwe eriri igwe dị elu na njikọ oghere maka akụrụngwa X-ray ahụike |
IEC 60522:1999 | Mkpebi nke nzacha na-adịgide adịgide nke mgbakọ tube X-ray |
IEC 60613-2010 | Njirimara eletriki, thermal na loading nke tubes X-ray anode na-atụgharị maka nyocha ahụike |
IEC60601-1: 2006 | Akụrụngwa eletriki ahụike - Nkebi 1: Ihe achọrọ maka nchekwa bụ isi na arụmọrụ dị mkpa |
IEC 60601-1-3: 2008 | Ngwa eletriki ahụike - Nkebi 1-3: Ihe ndị achọrọ maka nchekwa bụ isi na arụmọrụ dị mkpa |
IEC60601-2-28:2010 | Ngwa eletriki ahụike - Nkebi 2-28: Ihe ndị achọrọ maka nchekwa bụ isi na arụmọrụ dị mkpa nke mgbakọ X-ray tube maka nyocha ahụike. |
IEC 60336-2005 | Akụrụngwa eletriki ahụike- Mgbakọ tube X-ray maka nyocha ahụike-Ụdị ebe ntụpọ |
●Edebere aha ya dị ka ndị a:
MWHX7360 | Tube | A | Igwe ọkụ dị elu nwere ntụzịaka ogo 90 |
MWTX73-0.6/1.2-150H | B | Igwe ọkụ dị elu nwere ntụzịaka ogo 270 |
Ngwongwo | Nkọwapụta | Ọkọlọtọ | |
Ike ntinye aha nke anode | F 1 | F 2 | IEC 60613 |
20kW (50/60Hz) 30kW (150/180Hz | 50kW (50/60Hz) 74kW (150/180Hz) | ||
Ike nchekwa okpomọkụ anode | 212kJ (300kHU) | IEC 60613 | |
Ike kachasị mma nke anode | 750W | ||
Ike nchekwa ọkụ | 900kJ | ||
Oke. okpomọkụ na-aga n'ihu na-enweghị ikuku- okirikiri | 180W | ||
Ihe anodeIhe mkpuchi elu anode | Rhenium-Tungsten-TZM(RTM) Rhenium-Tungsten (RT) | ||
Akụkụ ebumnuche (Ntụgharị: axis ntụaka) | 12 Celsius | IEC 60788 | |
Mgbakọ tube X-ray filtration pụtara | 1.5 mm Al / 75kV | IEC 60601-1-3 | |
Uru aha (s) n'ebe ntụpọ | F1 (obere elekwasị anya) | F2 (nnukwu uche) | IEC 60336 |
0.6 | 1.2 | ||
X-ray tube nominal voltajiRadiographicFluoroscopic | 150kV 125kV | IEC 60613 | |
Data na kpo oku cathode Oke. ugbu a Oke voltaji | ≈ / AC, <20 kHz | ||
F1 | F 2 | ||
5.4A ≈9V | 5.4 A ≈17V | ||
Nhapu radieshon na 150 kV/3mA na anya 1m | ≤1.0mGy/h | IEC60601-1-3 | |
Mpaghara radieshon kacha |
430×430mm na SID 1m | ||
X-ray tube mgbakọ arọ | Ihe ruru. 18 n'arọ |
Oke | Oke ọrụ | Oke njem na nchekwa |
Ọnọdụ okpomọkụ | Site na 10℃ruo 40℃ | Site na -20℃to 70℃ |
Iru mmiri dị ala | ≤75% | ≤93% |
Mmetụta barometric | Site na 70kPa ruo 106kPa | Site na 70kPa ruo 106kPa |
1-phase stator
Ebe ule | C-M | C-A |
Nguzogide ikuku | ≈18.0…22.0Ω | ≈45.0…55.0Ω |
Voltaji na-arụ ọrụ nke ukwuu (agba ọsọ) | 230V± 10% | |
Kwado voltaji na-arụ ọrụ(gbalite) | 160V± 10% | |
voltaji breeki | 70VDC | |
Na-agba ọsọ voltaji na ikpughe | 80Vrms | |
Voltaji na-agba ọsọ na fluoroscopy | 20V-40Vrms | |
Oge ịgba ọsọ (dabere na usoro mmalite) | 1.2s |
Ịdọ aka ná ntị iji jiri X-ray Generator mee ihe
1. Ụlọ mgbawa
Etinyekwala ike karịrị ike ọ bụla na mgbakọ tube X-ray
Ọ bụrụ na ntinye ike karịrị tube nkọwapụta, ọ na-akpata okpomọkụ nke anode, fanye tube iko agbajikwa na n'ikpeazụ ndị na-esonụ oké nsogbu n'ihi na-amụba n'elu-nrụgide site mmanụ vaporization n'ime ụlọ nzukọ.
N'ọnọdụ dị oke egwu na-akpata mgbawa ụlọ site n'elu ibu, nchekwa ọkụ ọkụ enweghị ike ichebe tube X-ray ọbụlagodi na ọ na-arụ ọrụ.
*Ụlọ akara akụkụ mgbawa.
*Mmerụ mmadụ gụnyere ọkụ n'ihi mgbapụ mmanụ ọkụ.
*Ihe mberede ọkụ n'ihi ebumnuche anode na-ere ọkụ.
Igwe ọkụ X-ray kwesịrị inwe ọrụ nchekwa nke na-ejikwa ike ntinye ka ọ dịrị n'ime nkọwapụta tube.
2.Electric Ujo
Iji zere ihe egwu nke ujo eletrik, akụrụngwa a ga-ejikọrịrị na ọkọnọ nwere ụwa nchebe.
3.Ọ dịghị mgbanwe nke ngwá ọrụ a na-ekwe !!
Kpachara anya ka ị jiri X-ray Generator mee ihe
1.Over Rating
Enwere ike ịgbaji mgbakọ tube X-ray site n'itinye naanị otu ogbugba agbagoro agbagoro.
Biko gụọ akwụkwọ ụbọchị teknụzụ nke ọma wee soro ntuziaka.
2.Nzacha na-adịgide adịgide
TA na-ahazi nzacha niile na anya dị n'etiti ebe X-ray focal spot na ahụ mmadụ n'ụzọ iwu kwadoro.
They kwesịrị irubere iwu.
3.Nchekwa ọkụ ọkụ
Mgbakọ tube X-ray nwere mgba ọkụ ọkụ na-echebe iji gbochie ike ntinye ọzọ mgbe ụlọ tube ruru na okpomọkụ(80℃)nke mgba ọkụ-emeghe.
A naghị atụ aro ka mgba ọkụ ahụ jikọọ eriri stator na sekit usoro.
Ọbụlagodi na mgba ọkụ na-arụ ọrụ, agbanyụla sistemu ike. Ekwesịrị ịgbalite nkeji jụrụ oyi ma ọ bụrụ na ejiri ya na sistemụ.
4.Atụghị anya malfunction
Mgbakọ tube X-ray nwere ike ịnwe ihe ize ndụ nke na-arụ ọrụ na-atụghị anya ya n'ihi nkwụsị ndụ ma ọ bụ ọdịda. Ọ bụrụ na a na-atụ anya nsogbu siri ike nke ihe ize ndụ dị n'elu kpatara, a na-arịọ gị ka ị nwee atụmatụ nchebe iji zere ụdị ikpe ahụ.
5. Ngwa ọhụrụ
Ọ bụrụ na ị na-eji ngwaahịa ahụ nwere ngwa ọhụrụ agaghị ekwupụta ya na nkọwapụta a ma ọ bụ ụdị generator X-ray dị iche iche, biko kpọtụrụ anyị ka anyị kwenye na ọ dị.
1 .X-ray Radiationnchebe
Ngwaahịa a na-emezu ihe achọrọ nke IEC 60601-1-3.
Mgbakọ tube X-ray a na-ewepụta radieshon X-ray na-arụ ọrụ. Naanị ndị ọrụ ruru eru na ndị zụrụ azụ ka a na-ahapụ ka ha rụọ mgbakọ tube X-ray.
Mmetụta physiologic dị mkpa nwere ike imerụ onye ọrịa ahụ, nrụpụta sistemụ kwesịrị ịnwe nchebe kwesịrị ekwesị iji zere radieshon ionization.
2.Dielectric 0il
Mgbakọ tube X-ray nwere dielectric 0il dị maka nkwụsi ike dị elu. Dị ka ọ na-egbu egbu maka ahụ ike mmadụ,ọ bụrụ na ekpughere ya na mpaghara enweghị mmachi,a ga-atụfu ya dịka usoro iwu obodo.
3 .Operation Atmosphere
A naghị ekwe ka e jiri mgbakọ x-ray tube mee ihe na ikuku gas na-ere ọkụ ma ọ bụ nke na-emebi emebi ·
4.Gbanwee tube ugbu a
Dabere na ọnọdụ ọrụ,enwere ike gbanwee njirimara filament.
Mgbanwe a nwere ike imetụta mkpughe nke oke ọnụ na mgbakọ tube X-ray.
Iji gbochie mgbakọ tube X-ray mebiri emebi,gbanwee tube ugbu a mgbe niile.
E wezụga mgbe X-ray tube nwere arcing Nsogbu na aleji oge eme ihe,chọrọ mgbanwe nke tube ugbu a.
5.X-ray Tube Okpomọkụ Ebe obibi
Emetụkwala n'elu ụlọ ụlọ X-ray tube obere oge ka arụchara ọrụ n'ihi oke okpomọkụ.
Nọgidere tube X-ray ka ọ dị jụụ.
6Oke ọrụ
Tupu eji,biko gosi na ọnọdụ gburugburu ebe obibi dị n'ime Imitts na-arụ ọrụ.
7.Arụ ọrụ ọ bụla
P1ease kpọtụrụ SAILRAY ozugbo,ọ bụrụ na achọpụtara adịghị arụ ọrụ ọ bụla nke mgbakọ tube X-ray.
8.Mkpofu
The X-ray tube mgbakọ nakwa dị ka tube nwere ihe ndị dị ka mmanụ na arọ ọla nke na gburugburu ebe obibi enyi na enyi na kwesịrị ekwesị mkpofu na dị na nti mba iwu ụkpụrụ ga-emesi.Ntufu dị ka anụ ụlọ ma ọ bụ ulo oru iju bụ forbidden.The emeputa nwere chọrọ oru ihe ọmụma na ga-ewe X-ray tube mgbakọ azụ maka mkpofu.
Biko kpọtụrụ ndị ahịa maka ebumnuche a.
Ọ bụrụ (A) Obere ntụpọ
Ọ bụrụ na (A) Nnukwu Ebe Focal
Njirimara okpomọkụ nke ụlọ
SRMWHX7360A
Mgbakọ nzacha na ngalaba Cross Port
Rotor Njikọ Wiring
Ọnụ ego kacha nta: 1pc
Ahịa: mkparita uka
Nkọwa ngwugwu: 100pcs kwa katọn ma ọ bụ ahaziri dị ka ọnụọgụgụ
Oge nnyefe: 1 ~ 2 izu dị ka ọnụọgụgụ
Usoro ịkwụ ụgwọ: 100% T / T n'ihu ma ọ bụ WESTERN UNION
Ịkwanye ikike: 1000pcs / ọnwa