China X-ray Tube Ụlọ Mgbakọ TOSHIBA E7239X Onye nrụpụta na onye na-eweta ngwaahịa |Ụgbọ mmiri
Mgbakọ Ụlọ X-ray Tube TOSHIBA E7239X

Mgbakọ Ụlọ X-ray Tube TOSHIBA E7239X

Mgbakọ Ụlọ X-ray Tube TOSHIBA E7239X

Nkọwa dị mkpirikpi:

◆ Mgbakọ tube X-ray maka nyocha nyocha oge niile na redio redio dijitalụ ma ọ bụ redio na fluoroscopic.

Atụmatụ ntinye: 16° ​​Rhenium-Tungsten molybdenum lekwasịrị anya (RTM)

◆ Ebe ntụpọ: Obere 1.0, Nnukwu: 2.0

◆ Oke voltaji tube:125kV

◆ Ejiri ụdị IEC60526 nweta ihe nkwụnye ọkụ dị elu.

◆Elu voltaji generator kwesịrị kwekọọ na IEC60601-2-7

Nhazi IEC (IEC 60601-1: 2005): Ngwa Klas M ME


Nkọwa ngwaahịa

Usoro ịkwụ ụgwọ & Mbupu:

Mkpado ngwaahịa

Iwu, ụkpụrụ na ụkpụrụ

Emepụtara ma mepụta ngwaahịa a na nkwekọrịta na iwu, ntụzịaka na ụkpụrụ imewe:
◆ Ntuziaka Council 93/42/EEC nke 14 June 1993 gbasara ngwaọrụ ahụike(akara CE).
TS EN ISO 13485 Ngwa ahụike - Sistemụ njikwa ogo - Ihe achọrọ maka usoro iwu.
ebumnuche..
TS EN ISO 14971 Ngwa ahụike - Ngwa njikwa ihe egwu na ngwaọrụ ahụike
TS EN ISO 15223-1 ngwaọrụ ahụike - akara iji jiri akara ngwaọrụ ahụike, akara na ozi a ga-enye - Nkebi 1: chọrọ izugbe
International Electrotechnical Commission (IEC), a na-atụle ụkpụrụ ndị a karịsịa.

Ntuziaka ọkọlọtọ

Ntuziaka ọkọlọtọ

Aha

EN 60601-2-54:2009 Ngwa eletriki ahụike - Nkebi 2-54: Ihe ndị achọrọ maka nchekwa bụ isi na arụmọrụ dị mkpa nke akụrụngwa X-ray maka redio na redio
IEC60526 Igwe eriri igwe dị elu na njikọ oghere maka akụrụngwa X-ray ahụike
IEC 60522:1999 Mkpebi nke nzacha na-adịgide adịgide nke mgbakọ tube X-ray
IEC 60613-2010 Njirimara eletriki, thermal na loading nke tubes X-ray anode na-atụgharị maka nyocha ahụike
IEC60601-1: 2006 Akụrụngwa eletriki ahụike - Nkebi 1: Ihe achọrọ maka nchekwa bụ isi na arụmọrụ dị mkpa
IEC 60601-1-3: 2008 Ngwa eletriki ahụike - Nkebi 1-3: Ihe ndị achọrọ maka nchekwa bụ isi na arụmọrụ dị mkpa
IEC60601-2-28:2010 Ngwa eletriki ahụike - Nkebi 2-28: Ihe ndị achọrọ maka nchekwa bụ isi na arụmọrụ dị mkpa nke mgbakọ X-ray tube maka nyocha ahụike.
IEC 60336-2005 Akụrụngwa eletriki ahụike- Mgbakọ tube X-ray maka nyocha ahụike-Ụdị ebe ntụpọ

Nkọwa

●Edebere aha ya dị ka ndị a:

MWHX7010

Tube

A

Igwe ọkụ dị elu nwere ntụzịaka ogo 90

MWTX70-1.0/2.0-125

B

Igwe ọkụ dị elu nwere ntụzịaka ogo 270

Data teknụzụ

Ngwongwo

Nkọwapụta

Ọkọlọtọ

Ike ntinye aha nke anode

F 1

F 2

IEC 60613

21kW (50/60Hz)

42.5kW (50/60Hz)

 

Ike nchekwa okpomọkụ anode

100kJ (140kHU)

IEC 60613

Ike kachasị mma nke anode

475W

 
Ike nchekwa ọkụ

900kJ

 
Oke.okpomọkụ na-aga n'ihu na-enweghị ikuku- okirikiri

180W

 
Ihe anodeIhe mkpuchi elu anode

Rhenium-Tungsten-TZM(RTM)

Rhenium-Tungsten (RT)

 
Akụkụ ebumnuche (Ntụgharị: axis ntụaka)

16 Celsius

IEC 60788

Mgbakọ tube X-ray filtration pụtara

1.5 mm Al / 75kV

IEC 60601-1-3

Uru aha (s) n'ebe ntụpọ

F1 (obere elekwasị anya)

F2 (nnukwu uche)

IEC 60336

1.0

2.0

 
X-ray tube nominal voltajiRadiographic

Fluoroscopic

125kV

100kV

IEC 60613

Data na cathode kpo oku 

Oke.ugbu a

Oke voltaji

≈ / AC, <20 kHz

 

F1

F 2

 

5.1A

≈5.87.8V

5.1 A

≈7.710.4 V

 
Nhapu radieshon na 150 kV/3mA na anya 1m

1.0mGy/h

IEC60601-1-3

Mpaghara radieshon kacha

573×573mm na SID 1m

 
X-ray tube mgbakọ arọ

Ihe ruru.18 n'arọ

 

 

Ọnọdụ maka ọrụ, nchekwa na njem

Oke

Oke ọrụ

Oke njem na nchekwa

Ọnọdụ okpomọkụ

Site na 10ruo 40

Site na -20to 70

Iru mmiri dị ala

≤75%

≤93%

Mmetụta barometric

Site na 70kPa ruo 106kPa

Site na 70kPa ruo 106kPa

 

Ụkpụrụ igodo Stator

1-phase stator

Ebe ule

C-M

C-A

Nguzogide ikuku

≈18.0…22.0Ω

≈45.0…55.0Ω

Voltaji na-arụ ọrụ nke ukwuu (agba ọsọ)

230V± 10%

Kwado voltaji na-arụ ọrụ(gbalite)

160V± 10%

voltaji breeki

70VDC

Na-agba ọsọ voltaji na ikpughe

80Vrms

Voltaji na-agba ọsọ na fluoroscopy

20V-40Vrms

Oge ịgba ọsọ (dabere na usoro mmalite)

1.2s

Ịdọ aka ná ntị

Ịdọ aka ná ntị iji jiri X-ray Generator mee ihe

1. Ụlọ mgbawa
Etinyekwala ike karịrị ike ọ bụla na mgbakọ tube X-ray
Ọ bụrụ na ike ntinye aka karịa nkọwa nke tube ahụ, ọ nwere ike ime ka anode na-ekpo ọkụ, iko tube na-agbaji, na n'ikpeazụ nwere ike ịkpata nsogbu siri ike n'ihi oke ọkụ na-akpata site na vaporization nke mmanụ n'ime mgbakọ ụlọ.N'ọnọdụ dị oke egwu ebe ụlọ na-agbaji n'ihi oke ibu, nchekwa ọkụ ọkụ nwere ike ọ gaghị echebe tube X-ray, ọ bụrụgodị na ọ na-arụ ọrụ.
Ụlọ akara akụkụ mgbawa.
Mmerụ mmadụ gụnyere ọkụ n'ihi mgbapụ mmanụ ọkụ.
Ihe mberede ọkụ n'ihi ebumnuche anode na-ere ọkụ.
Igwe ọkụ X-ray kwesịrị inwe ọrụ nchekwa nke na-ejikwa ike ntinye ka ọ dịrị n'ime nkọwapụta tube.

2.Electric Ujo
Iji zere ihe egwu nke ujo eletrik, akụrụngwa a ga-ejikọrịrị na ọkọnọ nwere ụwa nchebe.

 3.Ọ dịghị mgbanwe nke ngwá ọrụ a na-ekwe !!

Ịdọ aka ná ntị

Kpachara anya ka ị jiri X-ray Generator mee ihe

1. Over Rating
Ike dị ukwuu n'otu égbè nwere ike ime ka mgbakọ X-ray tube ghara ịdaba. Ọ dị mkpa iji nlezianya nyochaa mpempe akwụkwọ data teknụzụ ma soro ntuziaka akọwapụtara iji zere mmebi.

2.Nzacha na-adịgide adịgide
Usoro iwu na-akọwapụta mkpokọta nzacha achọrọ yana anya kacha nta n'etiti ebe a na-elekwasị anya X-ray na ahụ mmadụ.
They kwesịrị irubere iwu.

3.Nchekwa ọkụ ọkụ
Mgbakọ tube X-ray nwere mgba ọkụ ọkụ na-echebe iji gbochie ike ntinye ọzọ mgbe ụlọ tube ruru na okpomọkụ(80)nke mgba ọkụ-emeghe.
A naghị atụ aro ka mgba ọkụ ahụ jikọọ eriri stator na sekit usoro.
Ọbụlagodi na mgba ọkụ na-arụ ọrụ, agbanyụla sistemu ike.Ekwesịrị ịgbalite nkeji jụrụ oyi ma ọ bụrụ na ejiri ya na sistemụ.

4.Atụghị anya malfunction
Mgbakọ tube X-ray nwere ike ịrụ ọrụ nke ọma ma ọ bụ daa na mberede, na-ebute nsogbu nke nnukwu nsogbu.Ọ dị mkpa ịnwe atụmatụ nchekwa iji gbochie na dozie nsogbu ọ bụla nwere ike ibilite na ihe egwu a.

5. Ngwa ọhụrụ
Ọ bụrụ na ị na-eme atụmatụ iji ngwaahịa a na ngwa ọhụrụ akọwapụtaghị n'ime akwụkwọ a, ma ọ bụ ọ bụrụ na ị na-eme atụmatụ iji ụdị generator X-ray dị iche, biko kpọtụrụ anyị iji kwado ndakọrịta na ịdị adị.

Ịkpachara anya na arụ ọrụ

1 .X-ray Radiationnchebe

Ngwaahịa a na-emezu ihe achọrọ nke IEC 60601-1-3.

Mgbakọ tube X-ray a na-ewepụta radieshon X-ray na-arụ ọrụ. Naanị ndị ọrụ ruru eru na ndị zụrụ azụ ka a na-ahapụ ka ha rụọ mgbakọ tube X-ray.

Mmetụta physiologic dị mkpa nwere ike imerụ onye ọrịa ahụ, nrụpụta sistemụ kwesịrị ịnwe nchebe kwesịrị ekwesị iji zere radieshon ionization.

2.Dielectric 0il

Mgbakọ tube X-ray nwere dielectric 0il dị maka nkwụsi ike dị elu.Dị ka ọ na-egbu egbu maka ahụ ike mmadụ,ọ bụrụ na ekpughere ya na mpaghara enweghị mmachi,a ga-atụfu ya dịka usoro iwu obodo.

3 .Operation Atmosphere

A naghị ekwe ka e jiri mgbakọ x-ray tube mee ihe na ikuku gas na-ere ọkụ ma ọ bụ nke na-emebi emebi ·

4.Gbanwee tube ugbu a

Dabere na ọnọdụ ọrụ,enwere ike gbanwee njirimara filament.

Mgbanwe a nwere ike imetụta mkpughe nke oke ọnụ na mgbakọ tube X-ray.

Iji gbochie mgbakọ tube X-ray mebiri emebi,gbanwee tube ugbu a mgbe niile.

E wezụga mgbe X-ray tube nwere arcing Nsogbu na aleji oge eme ihe,chọrọ mgbanwe nke tube ugbu a.

5.X-ray Tube Okpomọkụ Ebe obibi

Emetụkwala n'elu ụlọ ụlọ X-ray tube obere oge ka arụchara ọrụ n'ihi oke okpomọkụ.

Nọgidere tube X-ray ka ọ dị jụụ.

6Oke ọrụ

Tupu eji,biko gosi na ọnọdụ gburugburu ebe obibi dị n'ime Imitts na-arụ ọrụ.

7.Arụ ọrụ ọ bụla

P1ease kpọtụrụ SAILRAY ozugbo,ọ bụrụ na achọpụtara adịghị arụ ọrụ ọ bụla nke mgbakọ tube X-ray.

8.Mkpofu

Mgbakọ tube X-ray yana tube nwere ihe ndị dị ka mmanụ na ọla dị arọ nke a ga-emesi obi ike na gburugburu ebe obibi enyi na ikpofu kwesịrị ekwesị dị ka ụkpụrụ iwu obodo siri dị. ihe ọmụma teknụzụ achọrọ ma ga-eweghachi mgbakọ tube X-ray maka mkpofu.

Biko kpọtụrụ ndị ahịa maka ebumnuche a.

Emission akụkụ nke cathode

图片 18
图片 18

Ọ bụrụ (A) Obere ntụpọ

Ọ bụrụ na (A) Nnukwu Ebe Focal

Ibu otu na usoro

Ọnọdụ: Tube Voltage Nkeji atọ

Ugboro ike Stator 50Hz/60Hz

图片 20
图片 22

Kpo oku na obi jụrụ akụkụ nke anode

  IEC60613

图片 23

Kpọọ ọkụ na nju oyi nke mgbakọ tube X-ray

Njirimara okpomọkụ nke ụlọ

图片 24

X-ray tube mgbakọ akụkụ eserese

SRMWHX7010A

图片 25

SRMWHX7010B

图片 26

Mgbakọ nzacha na ngalaba Cross Port

图片 27

Rotor Njikọ Wiring

图片 28

  • Nke gara aga:
  • Osote:

  • Ọnụ ego kacha nta: 1pc

    Ahịa: mkparita uka

    Nkọwa ngwugwu: 100pcs kwa katọn ma ọ bụ ahaziri dị ka ọnụọgụgụ

    Oge nnyefe: 1 ~ 2 izu dị ka ọnụọgụgụ

    Usoro ịkwụ ụgwọ: 100% T / T n'ihu ma ọ bụ WESTERN UNION

    Ịkwanye ikike: 1000pcs / ọnwa

    Dee ozi gị ebe a ziga anyị ya